Beckhoff CX50x0 Bedienungsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 77
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
Notes on the documentation
CX50x0 - Hardware Documentation 21
FUNCTION_BLOCK FB_NT_QuickShutdown
The function block FB_NT_QuickShutdown is used to immediately reboot the PC without stopping TwinCAT or the
operating system Windows.
Attention:
The function block FB_NT_QuickShutdown is used internally from FB_S_UPS and is not intended to be used
elsewhere!
FUNCTION_BLOCK FB_NT_QuickShutdown
VAR_INPUT
VAR_INPUT
NETID :T_AmsNetId;
START :BOOL;
TMOUT :TIME := DEFAULT_ADS_TIMEOUT;
END_VAR
NETID : AmsNetID of the PC.
START : rising edge leads to an immediate reboot of the PC.
TMOUT : Timeout time.
VAR_OUTPUT
VAR_OUTPUT
BUSY :BOOL;
ERR :BOOL;
ERRID :UDINT;
END_VAR
BUSY : The QuickShutdown is being executed.
ERR : Is TRUE, if an error occurs.
ERRID : Delivers the error number in case that ERR is TRUE.
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 76 77

Kommentare zu diesen Handbüchern

Keine Kommentare