Beckhoff Lightbus Coupler BK2000 valid for all BK2xxx bus coupler Technical Documentation 2006-11-27 Version 1.4
Basic information 10 BK2000 Mechanical construction The Beckhoff bus terminal system is remarkable for its compact construction and
Basic information BK2000 11 Insulation test PE power contacts The connection between bus couplers and bus terminal
Basic information 12 BK2000 The peripheral data in the process image The bus coupler features different memory areas that possess a
Basic information BK2000 13 Special signals and interface The BK2000 supports bus terminals with further interfaces such as RS232, RS485, incre
Basic information 14 BK2000 The path from the I/Os to the Beckhoff-Lightbus process image Mapping list Mapping listMapping Mappingby byte by bit
Basic information BK2000 15 Starting operation and diagnostics The bus coupler immediately checks the connected configuration after s
Basic information 16 BK2000 BK2000 diagnostic LEDs Attention must be paid to the fact that there is a connection between the green I/
Beckhoff-Lightbus coupler BK2000 BK2000 17 Beckhoff-Lightbus coupler BK2000 Presentation of the Beckhoff-Lightbus system The Beckhoff-Lig
Beckhoff-Lightbus coupler BK2000 18 BK2000 The master interfaces can be subdivided into two fundamental groups, the PC boards C1200 and C1220 and t
Beckhoff-Lightbus coupler BK2000 BK2000 19 The contents "00" only enable "Page 0 READ accesses". In later master v
Contents 2 BK2000 Contents 1. Foreword 3 Notes on the documentation 3 Liability Conditions 3 Delivery conditions 3 Copyright 3 Safety Instr
Beckhoff-Lightbus coupler BK2000 20 BK2000 The BK2xxx bus couplers Bit Description support the status D2.0 Command error messages via the D2.1 I
Beckhoff-Lightbus coupler BK2000 BK2000 21 The Int command can also be triggered by a broadcast telegram. The master can therefore
Beckhoff-Lightbus coupler BK2000 22 BK2000 Fundamental characteristics The medium of fiber-optic transmission Network topology Ring system, activ
Beckhoff-Lightbus coupler BK2000 BK2000 23 Configuration software Interface type Interface designation Configuration software for master confi
Annex 24 BK2000 Annex Example: combination of a process image in the bus coupler An example explains how the input and output cha
Annex BK2000 25 Part for byte-oriented data, analog inputs Relative byte address Bit position Process image in the controller Position in the b
Annex 26 BK2000 enables allocation of the bytes to the addresses of the controller's process image. The control/status bytes of the anal
Annex BK2000 27 Representation of the analog signals in the process image Three input bytes and three output bytes of the process image
Annex 28 BK2000 Register set of an 63 analog channel 47 31 15 User area 16 0 OFF SET
Annex BK2000 29 Special case with older software versions or older driver software Used with older software or with driver software
Foreword BK2000 3 Foreword Notes on the documentation This description is only intended for the use of trained specialists in control and automat
Support and Service 30 BK2000 Support and Service Beckhoff and their partners around the world offer comprehensive support and service, making ava
Foreword 4 BK2000 Safety Instructions State at Delivery All the components are supplied in particular hardware and software configuration
Basic information BK2000 5 Basic information The Beckhoff bus terminal system Up to 64 bus terminals each with 2 I/O channels for any form
Basic information 6 BK2000 for separately powered groups You can use power input terminals to subdivide the terminal row as desired into groups,
Basic information BK2000 7 The interfaces There are six ways of making a connection to a bus coupler. These interfaces are design
Basic information 8 BK2000 Field bus connection Beckhoff-Lightbus fiber-optic conductor ring Beckhoff Z1000 connector There is a recessed f
Basic information BK2000 9 The operating modes of the bus coupler When it is first switched on the bus coupler carries out a self-test to che