Seite 1 - CP62xx-xxxx-0030/-0035/-0040

Installation and Operating instructions for Economy Built-in Panel PC CP62xx-xxxx-0030/-0035/-0040 Version: 1.1 Date: 2012-04-0

Seite 2 - Table of contents

Product Description Extension for modules or plug-in cards Order option When ordered with the following options the build-in Panel PC CP62xx can

Seite 3 - Appendix 27

Product Description Access to the PCI-/ PCIe plug-in card slots Switch off power supply Attention When components are being fitted or removed,

Seite 4 - Foreword

Installation Instructions Installation Instructions Please also refer to chapter Foreword. Transport and Unpacking The specified storage condi

Seite 5

Installation Instructions Installation of the PC in the control cabinet The Built-in Panel PC CP62xx is designed for mounting in control cabin

Seite 6 - Basic safety measures

Installation Instructions Mounting of the Panel-PC Please refer to the tables for Panel-PC cutout dimensions. Mounting of the Panel-PC Clamping

Seite 7 - Operator requirements

Installation Instructions Power Supply Connection Supplied mains power unit The Industrial PC is fitted with a 24 VDC power supply unit . Uninte

Seite 8 - Product Description

Installation Instructions In order to maintain a screen display for the Industrial PC in the event of a power failure, the power supply unit is

Seite 9 - Ground connection

Installation Instructions Fitting the cable Wiring in accordance with wiring diagram Fit the cables for the power supply of the Industrial PC, th

Seite 10

Installation Instructions Connecting Power Supply The external wiring consists of the connection of the power supply, the battery pack (optiona

Seite 11

Installation Instructions Wiring diagram Wiring according to the wiring diagram (the circuit of PC_ON and Power-Status is symbolical): Wiring di

Seite 12 - Installation Instructions

Table of contents Table of contents 1. 2. 3. 4. Foreword 3 Notes on the Documentation 3 Liability Conditions 3 Trademarks 3 Patent Pending 3 Co

Seite 13 - Earthing measures

Installation Instructions Connecting devices Power supply plug Attention The power supply plug must be withdrawn! Please read the documentation

Seite 14 - Mounting of the Panel-PC

Operating Instructions Operating Instructions Please also refer to chapter Foreword. Switching the Industrial PC on and off Switch on The Indu

Seite 15 - Power Supply Connection

Operating Instructions Keyboard codes Type-dependent number of keys Depending on the precise type, the Control Panel can have fewer keys than tho

Seite 16

Operating Instructions F1 F2 F3 F4F5 F6 F7 F8F9 F1 0 F1 1 F1 2 The meaning of the function keys, F1 to F10, is determined by the software and is

Seite 17 - Fitting the cable

Operating Instructions Servicing and maintenance Please also refer to chapter Foreword. Cleaning the Industrial PC Disconnect from power sup

Seite 18 - Connecting Power Supply

UPS Software Components (optional) UPS Software Components (optional) Installing the UPS driver software For operating the power supply unit as a

Seite 19 - Wiring diagram

Troubleshooting Troubleshooting Please also refer to chapter Foreword. Pixel errors Note Pixel errors in the TFT display are production-caused

Seite 20 - Connecting devices

Troubleshooting Beckhoff Support & Service Beckhoff and their partners around the world offer comprehensive support and service, guaranteei

Seite 21 - Operating Instructions

Appendix Appendix Assembly dimensions Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagram

Seite 22 - Pg Up Pg Dn

Appendix Assembly dimensions with module slot option Notice mounting orientation Attention The assembly of the unit must take place with the ori

Seite 23 - F9 F1 0 F1 1 F1 2

Table of contents Cleaning the Industrial PC 23 Servicing 23 Replacing the battery on the motherboard 23 Emergency procedures 23 Shutting down

Seite 24 - Shutting down

Appendix Assembly dimensions with plug-in card slot option Notice mounting orientation Attention The assembly of the unit must take place with t

Seite 25 - Help files

Appendix 30 CP62xx-xxxx-0030/-0035/-0040 Technical data Dimensions Dimensions (W x H x D): see section Assembly dimensions. Operation in are

Seite 26 - Troubleshooting

Foreword Foreword Notes on the Documentation This description is only intended for the use of trained specialists in control and automation engi

Seite 27

Foreword Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to

Seite 28 - Appendix

Foreword Basic safety measures Only switch the PC off after closing the software Before the Industrial PC is switched off, software that is runni

Seite 29 - Assembly dimensions

Foreword Operator’s obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended purpose (

Seite 30

Product Description Product Description Appropriate Use The CP62xx Build-in Panel PC is designed for industrial application in machine and plant

Seite 31 - Approvals

Product Description Additional plug-in cards (optional) Type plate There is a type plate on the top of the Industrial PC which provides informati