Seitenansicht 6
C1120 S5 to II/O Lightbus Interface Beckhoff II/O-Lightbus System
Date 27.06.97 Version 2.1 Page 7 of 52
2.3 Master Setup
The master setup menu is accessed by pressing F2 key from the main menu. With this menu,
the address mapping between the II/O-Lightbus system and the SIEMENS PLC is displayed
and can be edited, saved under a project name and transfered from and to the C1120 card.
The screen shows different fields for input, status line and function key setup.
Function keys:
F1 HELP
Shows a help text for the equivalent menu and function keys.
F2 EDIT CONFIGURATION
with this menu you can change the C1120 configuration.
F3 EDIT I/O LIST
with this menu you can modify the I/O address map list.
F4 TIMER & INTERRUPTS
with this menu you can configure the four fast fieldbus interrupts of the Beckhoff
II/O Lightbus System.