Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149
Software description of functions 20
Beckhoff Lightbus - PC interface card C1220
ArgumentChannel Length Function
0 1 2 3 4
Request
07 0x0f 0m Criterion
for
interrupt
channel 0
Criterion
for
interrupt
channel 1
Criterion
for
interrupt
channel 2
Criterion
for
interrupt
channel 3
Reply
03 0x0f 0m
The LOW nibble in the argument 0 specifies which of the 4 possible
interrupt channels is to be enabled.
Example: m = 0x00 all interrupt channels disabled (Default)
m = 0x01 Interrupt channel 0 enabled
m = 0x06 Interrupt channels 1 and 2 enabled
m = 0x0f Interrupt channels 0, 1, 2 and 3 enabled
Each interrupt channel can be characterized by way of a criterion.
The following criteria can be selected:
Criterion Interrupt-Channel
(0,1,2,3)
no Interrupt
0
Interrupt on positive edge
1
Interrupt on negative edge
2
Interrupt on edge change
3
The respective criteria are assigned to the interrupt channels by way of the
arguments 1 to 4.
Example:
ArgumentChannel Length Function
0 1 2 3 4
Request
07 0x0f 0x0c 00 00 01 03
Interrupt enabling for channels 2 and 3
Interrupt criterion for interrupt channel 0
no interrupt transfer
Interrupt criterion for interrupt channel 1
no interrupt transfer
Interrupt criterion for interrupt channel 2
Interrupt transfer with a positive edge
Interrupt criterion for interrupt channel 3
Interrupt transfer with an edge change