Beckhoff C1300 Bedienungsanleitung Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
C1300 VME to II/O Interface Unit Beckhoff II/O-System
Page 22 of 44 Version : 2.01 Date : 18.12.95
Funktion 07
h
: Address test
This function is used to prove if the modules still hold the address, they received
when they were initialized.
channel length function argument
0
argument
1
argument
2
comment
call
02 07
response
04 07 00 00
addresses correct
04 07 01 nn
error at address nn
In order to keep a maximum of safety for the system, this function is even run
resident when the system is working normally. In case an error is detected a
message is transmitted through the GCB to the VME system.
Seitenansicht 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 43 44

Kommentare zu diesen Handbüchern

Keine Kommentare