Technical data
22 C9900-G0xx
6 Technical data
DANGER
Risk of explosion!
The push-button extension must not be used in potentially explosive atmospheres!
Product designation C9900-G0xx
Supply voltage 24 V
DC
(20,4 – 28,8 V
DC
)
Min. operating voltage AC/DC 5 V
Max. operating voltage AC/DC 35 V
Min. operating current AC/DC 1 mA
Max. operating current AC/DC 100 mA
Switching capacity max. 250 mW
UL compliance
(in preparation)
Use a class 2 power supply, or
Protection via a 4 A fuse, according to UL 60950.2
section 2.5, table 2C
Interface USB 2.0 interface
Protection class Front IP65, rear IP65
Shock resistance
(sinusoidal vibration)
EN 60068-2-6: 10 to 58 Hz: 0.035 mm
58 to 500 Hz: 0.5 G (~ 5 m/ s²)
Shock resistance (shock) EN 60068-2-27: 5 G (~ 50 m/ s²), duration: 30 ms
EMC - interference immunity According to EN 61000-6-2
EMC interference emission According to EN 61000-6-4
Permitted ambient temperature 0 to +55°C (operation); CP3919/ CP3924: 0 to +50 °C (operation)
-25 to +65 °C (transport/storage)
Permissible relative humidity Maximum 95%, without condensation
Transport and storage The same values for atmospheric humidity and shock resistance are
to be observed during transport and storage as in operation. Suitable
packaging of the Control Panel can improve the resistance to impact
during transport.
Certifications CE, UL in preparation