Commissioning
2. FromthelistofthemanufacturersselectBeckhoffandasthemodelBeckhoffCX210009xx.
3. ClosethedialogwithFinishandconfirmwithApply.ThiswillcausetheUPSservicetoadoptthe
settingsandstarttheUPSservice.
4. Then,ontheBECKHOFFUPSconfigurationdialog,gotoAlarmconfiguration.
5. Activatethefollowingoptions(notabsolutelyessential).
Activateallnotifications:Thisoptionwillcausetheoperatingsystemtosendmessagestotheuser
wheneverthepowerfails(notavailableunderNT4.0).
Criticalalarm:Thealarmistriggeredoncethebatteryvoltagehasfallentoacertainleveloronce
batteryoperationhasexceededacertaintimelimit.Thisparametermustbesetto"0"fortheCX20x0
system.Itcanbesetto1minuteinexceptionalcases.
Executethefollowingprogramatanalarm:Thisoptioncanbeusedtoexecuteanapplicationwhen
analarmisraised(onlyavailableunderNT4.0iftheMicrosoftTaskSchedulerisinstalled).
Activatethefollowingoptions:
Minutesremainingforbatteryoperationbeforecriticalalarm:Thisoptioncanbeusedtospecify
thebatteryoperationtimeinminutesuntiltheCriticalalarmistriggered.Theshutdownoftheoperating
CX210009x444 Version1.1