9.3.4 Basic Setup
On the start screen click "Basic Setup" button.
Regen Resistor: Change only if you use an external regen resistor. Most applications
don't need an external regen resistor.
Max. Mains Voltage: Select the nominal mains AC voltage.
Mains Phase Missing: You can select either warning "n05" or error "F19" in case of
phase loss. The setting "F19" disables the output stage, "n05" is just a message.
Units: Acceleration, Velocity, Position
Select usable units for your application referring to the moved load.
Address:
Adjust for master amplifier only (= highest address of the drive system, see p.86)
Leave all other fields unchanged.
Click OK. On the start screen click "Motor" button.
80 AX2500 Product Manual
Setup 06/2007 BECKHOFF