Sub-index
03
h
Description
read upper limit value
Unit
see corresponding ASCII command
Access
ro
PDO mapping
not possible
Data type
see corresponding ASCII command
Value range
see corresponding ASCII command
EEPROM —
Default value —
Sub-index
04
h
Description
read the default value
Unit
see corresponding ASCII command
Access
ro
PDO mapping
not possible
Data type
see corresponding ASCII command
Value range
see corresponding ASCII command
EEPROM
—
Default value
—
Sub-index
05
h
Description
read the parameter format
Unit
—
Access
ro
PDO mapping
not possible
Data type
see corresponding ASCII command
Value range
see corresponding ASCII command
EEPROM
—
Default value
—
Description:
The following parameter formats are possible:
0 Function (no parameter)
1 Function (INTEGER32 parameter)
2 Function (INTEGER32 parameter with weighting 3)
3 INTEGER8
4 UNSIGNED8
5 INTEGER16
6,13 UNSIGNED16
7 INTEGER32
8,12 UNSIGNED32
9,10 INTEGER32 (weighting 3)
Note:
Parameters with parameter format 0 are read-only!