Seitenansicht 67
Sub-index
09
h
Brief description
resolution / numerator of the gearing ratio
Unit
μm
Access
rw
PDO mapping
not possible
Data type
UNSIGNED32
Value range
1 ... (2
32
-1)
Default value
1
The ratio of the values of Sub-indices 08
h
and 09
h
provides the mechanical resolution of the axis in
μm/turn.
Sub-index
0A
h
Brief description
count direction
Unit
Access
rw
PDO mapping
not possible
Data type
UNSIGNED8
Value range
0, 1
Default value
1
The value gives the count direction for current, speed, and position control. A value of 1 means that
the positive count direction has been selected. If a positive setpoint is provided, the motor shaft
rotates in a clockwise direction (looking at the shaft end).