SIDNs
S00160Accelerationdatascalingtype
Thisparametercanbeusedtoselectdifferentscalingtypesfortheaccelerationdatainthedrive.Thedrive
representsassociatedparametersattheselectedscale.
Attributes
Name Value
Format binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue 0xA
Unit
ChangeableinEtherCATstate No
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision
IntheAX5000,percentagescalingisselectedviaS00086"Torque/forcedatascalingtype".S00160is
thereforenotevaluated.
Bitpattern:
Bit Meaning
02 Scalingmethod
Scalingmethod
0=noscaling
1=linearscaling
2=rotaryscaling
3=ramptime(seeS00446)
3 Scalingtype
Scalingtype
0=preferredscaling
1=parameterscaling
4 Unitsforlinear/rotationalscaling
Unitsforlinear/rotationalscaling
0=meter/radian
1=inch/reserved
5 Timeunit
0=seconds
1=reserved
6 Datareference
0=atthemotorshaft
1=attheload
7
15
Reserved
Note
IDNsinvolved
S‐0‐0086 [}66],S‐0‐0160 [}118]