SIDNs
S00079Positionresolution
Thisparameterspecifiesthenumberofincrementsperturn(360°)forrotarymotors.TheLSBoftheposition
datathushasaweightingof360°deg/S00079.
Forlinearmotorsitspecifiesthenumberofincrementsperpolepitch(e.g.24mm).TheLSBoftheposition
datathushasaweightingof24mm/S00079.
Attributes
Name Value
Format udec
Datalength 32
Decimalpoint 0
Minvalue 1048576
Maxvalue 1048576,from204:1073741824
Defaultvalue 1048576
Unit
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision changedfrom204
InS00076,theAX5000allowsrotaryparameterweightingandthereforesupportsthisparameter.Upto
interface203thefollowingapplies:Thescalingcannotbechanged.Thefollowingsettingsareset:2
20
inc/
revolution=1048576inc/revolution.
Frominterface204thefollowingapplies:Thesingleturnresolutionofthedrivecanbeselectedbetween20
bitsand30bits.Example:Ifthesingleturnresolutionissetto22bits,10bitsremainforthemultiturn
resolution.Theoverallresolutionis32bits.
Value Text
1048576 2
20
Bit
2097152 2
21
Bit
4194304 2
22
Bit
8388608 2
23
Bit
16777216 2
24
Bit
33554432 2
25
Bit
67108864 2
26
Bit
134217728 2
27
Bit
268435456 2
28
Bit
536870912 2
29
Bit
1073741824 2
30
Bit
Note
IDNsinvolved
S‐0‐0076 [}55]
AX5000IDNDescriptions 57Version3.1