SIDNs
S00204Motorshutdowntemperature
Ifthetemperatureofthemotorexceedsthisvalue,thedrivesetserrorbit2ofS00011,andanerroris
generated.FD07"Motorovertemperatureshutdown"isissuedasthecorrespondingerrorcode.
Attributes
Name Value
Format udec
Datalength 16
Decimalpoint 1
Minvalue 0.0
Maxvalue 150.0
Defaultvalue 100
Unit °C
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Note
IDNsinvolved
S‐0‐0011 [}12]
AX5000IDNDescriptions 137Version3.1